STEINEL HF 3600 Manual Página 9

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 8
16 17
Wiring examples
1. Light without neutral lead 2. Light with neutral lead
3. Connection via series switch for
manual and automatic operation
4. Connection by a double-throw switch
for permanent light and automatic
mode
Setting I: automatic operation
Setting II: manual operation for
permanent light
Important: the unit cannot be switched off,
only optional operation between settings
I and II.
1) e.g. 1-4 x 100-W incandescent lamps
2) consumer, lighting max. 1000 W (refer to Technical specifi cations)
3) sensor connection terminals
4) indoor switch
5) indoor series switch, manual, automatic
6) indoor double-throw switch, automatic, permanent light
Troubleshooting
Malfunction Cause Remedy
Sensor
without power
Fuse blown,
not switched ON
Short circuit
Additional double-throw
switch OFF
Fuse blown
Replace fuse,
switch ON mains switch,
check lead with voltage
tester
Check connections
Switch ON
Replace fuse, check
connection if required
Sensor
does not switch ON
Bulb blown
Twilight setting in night-
time mode during day-
time operation
Additional double-throw
switch OFF
Fuse blown
Replace bulb
Readjust
Switch ON
Replace fuse, check
connection if required
Sensor
does not switch OFF
Continued movement in
detection zone
Permanent light ON
(red LED illuminates)
Further sensor switched
in parallel and still active
Check area
Switch off permanent
light
Wait for expiry of time
setting of the other
sensor
Sensor Switch
keeps switching ON/OFF
Curtains, fl owers, etc.
moving in the detec-
tion zone of the sensor
and switches again by
motion
Check area