STEINEL HF 3600 Manual Página 8

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 7
14 15
Installation of corner wall mount
Reach adjustment
(Sensitivity)
The desired reach of the
sensor can be continuously
adjusted from approx.
1 m to the maximum reach
of approx. 8 m. Adjusting
screw left stop position
means: minimum reach (ap-
prox. 1 m / factory setting).
Adjusting screw right stop
position means: maximum
reach (approx. 8 m).
The sensor can be installed
conveniently on inside and
outside corners using the
corner wall mounts pro-
vided. Use the corner wall
mount as a drilling template
when drilling the holes. In
this manner, the drilling hole
is set at the correct angle
and the corner wall mount
can be easily installed.
Functions
Time setting
(Switch-off delay)
The desired illumination
time of the connected
light can be continuously
adjusted from approx.
5 sec. to max. 30 min.
Adjusting screw left stop
position means: shortest
time approx. 5 sec. (factory
setting). Adjusting screw
right stop position means:
l
ongest time approx. 30 min.
The timer is started again
by any motion detected
before this time elapses.
During adjustment of the
detection zone and for
the performance test, it is
recommended to set the
shortest time.
Note: After every off
switching, further motion
detection is interrupted for
approx. 2 seconds. Only
after this time elapses can
the SensorSwitch switch
on light again in response
to motion.
Twilight setting
(Response threshold)
The desired response
threshold of the sensor can
be continuously adjusted
from approx. 2 lux to
2000 lux.
Adjusting screw right stop
position means: daylight
operation approx. 2000 lux
(factory setting). Adjusting
screw left stop position
means: nighttime operation
approx. 2 lux.
When adjusting the detec-
tion zone and for the per-
formance test in daylight,
the adjusting screw must
be set to the right stop
position.
Additional functions by a mains switch
If a mains switch is installed
in the supply lead, the
following functions are pos-
sible in addition to merely
switching ON and OFF of
the connected light.
Important: The switch
should be operated in rapid
succession (in the range
0.5 - 1 sec.).
1) Switch on the light:
Switch 2 x OFF and ON.
The light is set to perman-
ent light for 4 hours (red
LED illuminates behind
the lens). It subsequently
returns automatically to
sensor mode (red LED off).
2) Switch off light:
Switch 1 x OFF and ON.
The light goes out, or after
15 sec. transfers to sensor
mode.
4 hours
2 x OFF/ON
1) Switch on the light:
Switch 1 x OFF/ON.
The light remains on for
the set time.
2) Switch off the light:
Switch 1 x OFF and ON.
The connected light goes
out, or after 15 sec. trans-
fers to sensor mode.
5 sec. - 30 min.
1 x OFF/ON
2 - 2000 lux
5 sec. - 30 min.
1 - 8 m
Sensor operation
Permanent light
Vista de página 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 57 58

Comentários a estes Manuais